P40 AGILE MICOM P141 ALSTOM MiCOM P141 Feeder Management Protection Relay
ALSTOM MiCOM P40 Agile P141 numerical feeder protection relay, multi‑function overcurrent protection unit for overhead line & cable feeder in substation automation system.
Product Overview
- Part No: P40 AGILE MICOM P141
- Brand: ALSTOM / GE Vernova
Category: Numerical Feeder Management Protection RelayMiCOM P40 Agile P141 is a full‑featured numerical feeder protection relay under MiCOM P40 Agile protection platform. It integrates protection, measurement, control, fault recording and communication functions, developed for overhead lines and underground cable feeders of distribution and transmission substations. The unit supports complete overcurrent, earth‑fault and voltage protection logics, as well as auto‑reclose, breaker control and programmable scheme logic. It is fitted with local LCD HMI and multi‑color programmable LED indicators for onsite parameter configuration, status check and fault event review. Multiple standard industrial communication protocols are available for connection with SCADA and substation automation systems. It is widely used in power utilities, thermal power plants and industrial self‑power plants, acting as original replacement spare for old substation protection devices.
Core Features
- Multiple feeder protection functions: phase overcurrent, earth fault, negative‑sequence overcurrent, over‑voltage and under‑voltage protection
- Integrated auto‑reclosure, breaker failure detection and trip circuit supervision
- User‑definable programmable scheme logic to satisfy various site application demands
- Local LCD display, multi‑language human‑machine interface and configurable status LED indicators
- Rich communication options: IEC 61850, IEC 60870‑5‑103, Modbus, DNP3.0, Courier protocol
- Large‑capacity event log, fault records and disturbance oscillography for post‑fault analysis
- Multi setting groups for fast switching under different grid operating conditions
- Supports panel flush mounting and 19‑inch rack mounting for cabinet retrofit projects
High‑level EMC performance, qualified for vibration, shock and seismic requirements of harsh substation environment
Technical Specifications
- Auxiliary Supply: 80‑265 VAC / 87‑300 VDC
- Main Protection: Overcurrent, earth fault, voltage protection, auto‑reclosure
- Communication Protocols: IEC61850, IEC60870‑5‑103, Modbus RTU, DNP3.0, Courier
- Operating Temperature: ‑20°C ~ +60°C
- Front Panel Protection Grade: IP52
- Storage Temperature: ‑40°C ~ +85°C
Installation Type: Panel mount / 19 inch rack mount
Compatibility & Application
- Protect overhead lines and underground cable feeders for power distribution and transmission substations
- Applicable for public utility power grid, auxiliary system of thermal power plants, petrochemical and large‑scale industrial power facilities
- Compatible with mainstream substation automation and SCADA control platforms